Technica Specificationes
Productumdescriptio
Descriptio | Commutator Industrialis Administratus pro Ferrivia DIN, designatio sine ventilatore, Typus Fast Ethernet |
Versio Programmatis | HiOS 09.6.00 |
Genus et quantitas portus | Summa viginti portuum: 16 x 10/100BASE TX / RJ45; 4 x 100Mbit/s fibra; 1. Nexus ascendens: 2 x SFP slot (100 Mbit/s); 2. Nexus ascendens: 2 x SFP slot (100 Mbit/s) |
Plus Interfacies
Contactus signalis/fontis potentiae | 1 x terminale insertibile, 6-pin |
Ingressus Digitalis | 1 x terminale insertibile, 2-pin |
Administratio Localis et Substitutio Instrumentorum | USB-C |
Rete magnitudo - longitudo of funis
Par contortum (TP) | 0 - 100 metra |
Fibra unius modi (SM) 9/125 µm | vide modulos fibrae SFP vide modulos fibrae SFP |
Fibra monomodalis (LH) 9/125 µm (transceptor longae viae) | vide modulos fibrae SFP vide modulos fibrae SFP |
Fibra multimodalis (MM) 50/125 µm | vide modulos fibrae SFP vide modulos fibrae SFP |
Fibra multimodalis (MM) 62.5/125 µm | vide modulos fibrae SFP vide modulos fibrae SFP |
Rete magnitudo - cascabilitas
Topologia linearis/stellaris | ullus |
Potestasrequisita
Tensio Operativa | 2 x 12 VDC ... 24 VDC |
Consumptio energiae | XV W |
Potentia emissa in BTU (IT)/h | 51 |
Ambientiscondiciones
MTBF (TelecordiaSR-332 Fasciculus 3) @ 25°C | 2 972 379 horae |
Temperatura operandi | 0-+60 |
Temperatura repositionis/transportationis | -40-+70°C |
Humiditas relativa (non condensans) | 1-95% |
Mechanica constructio
Dimensiones (LxAxP) | 109 mm × 138 mm × 115 mm |
Pondus | 950 grammata |
Domus | PC-ABS |
Montatio | Ferrivia DIN |
Classis tutelae | IP30 |
Mechanica stabilitas
Vibratio secundum normam IEC 60068-2-6 | 5 Hz ... 8,4 Hz cum amplitudine 3,5 mm; 2 Hz ... 13,2 Hz cum amplitudine 1 mm; 8,4 Hz ... 200 Hz cum 1 g; 13,2 Hz ... 100 Hz cum 0,7 g. |
Impetus IEC 60068-2-27 | 15 g, duratio 11 ms |
EMC impedimentum immunitas
EN 61000-4-2 emissio electrostatica (ESD) | 6 kV emissione contactus, 8 kV emissione aeris |
EN 61000-4-3 campus electromagneticus | 10 V/m (80-2000 MHz); 5 V/m (2000-2700 MHz); 3 V/m (5100-6000 MHz) |
EN 61000-4-4 fastiria (irrumpunt) | Linea electrica 2 kV, linea datorum 2 kV |
Tensio impulsiva EN 61000-4-5 | linea electrica: 2 kV (linea/terra) et 1 kV (linea/linea); linea datorum: 2 kV |
EN 61000-4-6 Immunitas Conducti | 10 V (150 kHz-80 MHz) |
EMC emissus immunitas
EN 55022 | EN 55032 Classis A |
FCC CFR47 Pars 15 | FCC 47CFR Pars 15, Classis A |
Approbationes
Norma Fundamentalis | CE, FCC, EN61131, EN62368-1 |