Productumdescriptio
| Typus | GRS106-16TX/14SFP-2HV-3AUR (Numerus producti: GRS106-6F8F16TSGGY9HHSE3AURXX.X.XX) |
| Descriptio | GREYHOUND Series 105/106, Commutator Industrialis Administratus, designatio sine ventilatore, 19" in armario collocanda, secundum IEEE 802.3, Designatio 6x1/2.5/10GE +8x1/2.5GE +16xGE. |
| Versio Programmatis | HiOS 9.4.01 |
| Numerus Partis | 942287016 |
| Genus et quantitas portus | XXX Portus in summa, sex GE/2.5GE/10GE SFP(+) spatia + octo GE/2.5GE SFP spatia + sedecim portus FE/GE TX |
Plus Interfacies
| Contactus signalis/fontis potentiae | Ingressus alimentationis electricae 1: spina IEC, Contactus signalis: terminalis insertus 2 clavorum, Ingressus alimentationis electricae 2: spina IEC |
| Spatium pro scheda SD | 1 x foramen pro scheda SD ad adaptatorem configurationis automaticae ACA31 connectendum |
| USB-C | 1 x USB-C (cliens) ad administrationem localem |
Rete magnitudo - longitudo of funis
| Par contortum (TP) | 0-100 metra |
| Fibra unius modi (SM) 9/125 µm | vide modulos SFP |
| Fibra monomodalis (LH) 9/125 µm (transceptor longae viae) | vide modulos SFP |
| Fibra multimodalis (MM) 50/125 µm | vide modulos SFP |
| Fibra multimodalis (MM) 62.5/125 µm | vide modulos SFP |
Rete magnitudo - cascabilitas
| Topologia linearis/stellaris | ullus |
Potestasrequisita
| Tensio Operativa | Ingressus alimentationis electricae 1: 110-240 VAC, 50 Hz-60 Hz, Ingressus alimentationis electricae 2: 110-240 VAC, 50 Hz-60 Hz |
| Consumptio energiae | Unitas fundamentalis cum uno fonte potentiae maximo 35W |
| Potentia emissa in BTU (IT)/h | maximum 120 |
Ambientiscondiciones
| Temperatura operandi | -10 - +60 |
| Nota | 1 013 941 |
| Temperatura repositionis/transportationis | -20 - +70°C |
| Humiditas relativa (non condensans) | 5-90% |
Mechanica constructio
| Dimensiones (LxAxP) | 444 × 44 × 355 mm |
| Pondus | Quinque chiliogrammata aestimantur |
| Montatio | Montatio in armario |
| Classis tutelae | IP30 |
Mechanica stabilitas
| IEC 60068-2-6 vibratio | 3.5 mm, 5 Hz – 8.4 Hz, 10 cycli, 1 octava/min.; 1 g, 8.4 Hz – 200 Hz, 10 cycli, 1 octava/min. |
| Impetus IEC 60068-2-27 | 15 g, duratio 11 ms, 18 impulsus |
EMC impedimentum immunitas
| EN 61000-4-2 emissiones electrostaticae (ESD) | 6 kV emissione contactus, 8 kV emissione aeris |
| EN 61000-4-3 campus electromagneticus | 20 V/m (800-1000 MHz), 10 V/m (80-800 MHz; 1000-6000 MHz); 1 kHz, 80% AM |
| EN 61000-4-4 celer transitoria (eruptiones) | Linea electrica 2 kV, linea datorum STP 4 kV, linea datorum UTP 2 kV |
| Tensio impulsiva EN 61000-4-5 | linea electrica: 2 kV (linea/terra) et 1 kV (linea/linea); linea datorum: 2 kV |
| EN 61000-4-6 Immunitas Perducta | 10 V (150 kHz - 80 MHz) |
EMC emissus immunitas
| EN 55032 | EN 55032 Classis A |
Approbationes
| Norma Fundamentalis | CE, FCC, EN61131 |
| Salus instrumentorum technologiae informationis | EN62368, cUL62368 |
Hirschmann GRS 105 106 Series GREYHOUND Commutator Modela Disponibilia
GRS105-16TX/14SFP-2HV-3AUR
GRS105-24TX/6SFP-1HV-2A
GRS105-24TX/6SFP-2HV-2A
GRS105-24TX/6SFP-2HV-3AUR
GRS106-16TX/14SFP-1HV-2A
GRS106-16TX/14SFP-2HV-2A
GRS106-16TX/14SFP-2HV-3AUR
GRS106-24TX/6SFP-1HV-2A
GRS106-24TX/6SFP-2HV-2A
GRS106-24TX/6SFP-2HV-3AUR